1: Patching: Static cracks and surface defects should be repaired using SikaDur 33 Epoxy paste or other epoxy repair method subject to size and rectification required, all repairs should be finished smooth and flush with the concrete substrate: Please consult the
Sika Technical Department for further details or informaiton.
2:. Priming: An evaluation should be conducted to determine if double priming maybe required, once priming is completed the surface should be completely sealed with no presence of pinholes to ensure substrate outgassing does not continue in later applications. For ramps and falls extra broadcast material should be applied to slow the rate of flow for when wearing layer is to be applied.
Single Primer Applications : Mix and apply the Sikafloor 160 or 161 via a squeegee at the required thickness and back roll once applied to make even, Fill all pin holes and uneven surfaces, while still wet lightly broadcast the required washed and dried sand aggregate. Do not add thinners.
Double Primer Applications: 1st Application: Mix and apply Sikafloor 160 via a squeegee at the required thickness and back roll once
applied to make even. Fill all pin holes and uneven surfaces. 2nd Application: Mix and apply the Sikafloor 161, Sikafloor filler can be added to the Sikalfoor 161 at various addition rates to create a "Scratch Coat" mix.
3. Wearing Course: Mix the Full kit of Sikafloor 377 for 1 minute, then add between 7-10kg of Sikafloor filler and mix for a further 2 minutes (Addition rate is adjustable, subject to site and ambient conditions) apply with a V-Notch Squeegee to a minimum coverage of 1.5mm, a hand trowl can be used for edge, joint and drain, terminations, once installed a Spike Roller or 10- 12mm Nap paint roller should be used to even out the applied Sikafloor 377 to remove sgueegee marks and trowel edges to ensure a consistent and even coverage. Using Rounded Tip Spike Shoes, Broadcast the Sikafloor 377 with the Selected aggregate to refusal, there should be no glossy or bald spots.
Top Coats: NB: For best results the the application of top coats should be completed in 2 x applications, a sealer coat and final finish top coat, Sikafloor 377 Tinted can be used for the first sealer coat in order to keep costs down, with the final finish top coat of Sikafloor 359N required to provide UV stability.
4: Sealer Coat : After sweeping and vacuming to remove excess sand, Mix the Sikafloor 377 with the addition of 2 x 1.15kg Color Packs in the required color, Do not add fillers to the sealer coat. Apply with a medium rubber sgueegee, working accross the face, back and forth in single smooth motions, Using a 10- 12mm Nap Painters roller, back roll the floor to remove any drips and heavy applied matieral, once material has been evened out, use the un-loaded roller to "lay off the floor" taking care to lay the floor off in a single direction, working accross the flooring edge from end to end in a single smooth motion. Failure to lay the floor off in an effective mannor may result in a patchy or un-even finish,
5: Final UV stabel Top Coat Mix the Sikafloor 359 and apply with a medium rubber sgueegee, working accross the face, back and forth in single smooth motions, Using a 10- 12mm Nap Painters roller, back roll the floor to remove any drips and heavy applied matieral, once material has been evened out, use the un-loaded roller to "lay off the floor" taking care to lay the floor off in a single direction, working accross the flooring edge from end to end in a single smooth motion. Failure to lay the floor off in an effective mannor may result in a