Sikafloor® MultiDur ES-14
Sikafloor® MultiDur ES-14 is a multi-purpose - high build pigmented epoxy coating for Commercial and Industrial applications where a high degree of texture is not required
- Good chemical and mechanical resistance
- Good wear and abrassion resistance
- Easy application
- Liquid proof
- Gloss finish
- Easy cleanability
- Colour options
System Structure
1
Primer
2
Top Coat
Usage
- Production and process areas - dry
- Warhouses Garages
- Car storage facilities
- Aeronautical Manufacturing
- Cleanroom - Pharmaceutical
Advantages
- Good chemical and mechanical resistance
- Good wear and abrassion resistance
- Easy application
- Liquid proof
- Gloss finish
- Easy cleanability
- Colour options
Colour
Available in colours of RAL range on request
Standard colours: Light Grey 7035, Pebble Grey 7032, Koala Grey N45, Window Grey 7040, Dusty Grey 7037, Oxide Red 3009, Sky Blue 5015, Dahlia Yellow 1033
Appearance
Gloss finish
System Details
APPROVALS / CERTIFICATES
- Textures - Confroms to AS 4586-2013 P1 Rating
- VOC - Australian Standards ASTM D3960 Green Star Building Council V2 IEQ -13 V1 IEQ-11
- Fire Classification Australia - Critical Radiant Flux - Pass AS/ISO 9239-1 APVS 0209 Appendix B
System structure
Sikafloor® MultiDur ES-14
Layer | Product |
1. Primer | Sikafloor®-161/-160 |
2. Top coats | Sikafloor®-264 |
Composition
Epoxy
Nominal thickness
0.6–0.8 mm
Shore D Hardness
~76 (7 days / +23 °C) | (DIN 53 505) |
Abrasion resistance
~28 mg (CS 10/1000/1000) (7 days / +23 °C) | (DIN 53109) |
Tensile adhesion strength
> 1.5 N/mm² (failure in concrete) | (ISO 4624) |
Chemical resistance
Please refer to the chemical resistance chart of Sikafloor®- 264
Temperature resistance
Exposure* | Dry heat |
Permanent | +50 °C |
Short-term max. 7 d | +80 °C |
Short-term max. 12 h | +100 °C |
Short-term moist/wet heat* up to +80 °C where exposure is only occasional
(steam cleaning etc.)
*No simultaneous chemical and mechanical exposure.
Application
Material temperature
Please refer to the individual Product Data Sheet
Ambient air temperature
+10 °C min. / +30 °C max.
Relative air humidity
80 % r.h. max.
Dew point
Beware of condensation!The substrate and uncured floor must be at least 3 °C above dew point to reduce the risk of condensation or blooming on the floor finish.
Substrate temperature
+10 °C min. / +30 °C max.
Substrate moisture content
When performing application work with Sikafloor® MultiDur ES-14, the substrate moisture content must not exceed 4 % pbw measured by Tramex.Test method: Sika®-Tramex meter, CM - measurement or Oven-dry-method. No rising moisture according to ASTM (Polyethylene-sheet).
Use Sikafloor 161 Primer for moisture to 6%pbw.
For >6%pbw use Sikafloor 81 EpoCem.
Waiting time to overcoating
Before applying Sikafloor®-264 on Sikafloor® 161/-160 allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 24 hours | 3 days |
+20 °C | 12 hours | 2 days |
+30 °C | 8 hours | 1 day |
Before applying Sikafloor®-264 on Sikafloor®-264 allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 30 hours | 3 days |
+20 °C | 24 hours | 2 days |
+30 °C | 16 hours | 1 day |
Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
Applied product ready for use
Temperature | Foot traffic | Light traffic | Full cure |
+10 °C | ~ 72 hours | ~ 6 days | ~ 10 days |
+20 °C | ~ 24 hours | ~ 4 days | ~ 7 days |
+30 °C | ~ 18 hours | ~ 2 days | ~ 5 days |
Note: Times are approximate and will be affected by changing ambient conditions.
For faster cure and turnaround times use Sikafloor Booster.
Refer to Sika Techncal Dept. for direction
Consumption
Sikafloor® MultiDur ES-14 system
Coating System | Product | Consumption |
Primer | 1–2 × Sikafloor®-161/-160 | 1–2 × 0.35–0.55 kg/m² (5-6m2 Per L) |
Top coat | 1–2 × Sikafloor®-264 | 1–2 × 0.25–0.3 kg/m² (4-6m2 Per L)for each layer |
APPLICATION INSTRUCTIONS
For detailed application instructions refer to Sikafloor 160/161 and 264 TDS
SUBSTRATE PREPARATION
Prepare substrate to achieve a pull off value of >1.5mpa.
Any local imperfections should be filled using Sikafloor 160/161 with fillers.
Surface profile should be to CSP2 - approx.0.5mm in overall profile.
Profile should not be sufficient to impact on the final finish.
APPLICATION
Priming - Apply Sikafloor 160 or 161 to the correctly prepared substrate
Base layer - Appply Sikafloor 264 by roller in an even coat.
Finish coats - Apply final coat by roller to achieve an even smooth finish. Choice of roller knapp will slightly vary the finish. Knapp length of between 12 to 15mm is recommended. Cross rolling at 90 degrees is also recommended to achieve an even finish.
CLEANING
Please refer to the Method Statement Sikafloor®‐ Cleaning Regime